• Weida® UPS solar battery lithium ion valve regulated 100ah 200ah deep cycle lithium ion battery longer cycle life solar battery

    Weida® UPS solar battery lithium ion valve regulated 100ah 200ah deep cycle lithium ion battery longer cycle life solar battery

    The 12.8V200AH lithium iron phosphate (LiFePO4) battery is an outstanding choice for a variety of applications due to its superior performance characteristics. Here are some of its key features: High Energy Density: With a nominal energy of 2560Wh at 25°C, C10, this battery provides a substantial power reserve that can sustain high energy demands。 Extended Cycle Life: It boasts a cycle life of over 3000 cycles at 100% Depth of Discharge (DOD), and an impressive over 6000 cycles at 50% DOD, ensuring long-term reliability and reducing the need for frequent replacements。 Low Self-Discharge Rate: The self-discharge rate is less than 2% per month, which means the battery holds its charge well over extended periods, making it ideal for standby power applications。 Wide Operating Temperature Range: Capable of operating effectively in a broad temperature range from -20°C to 60°C for discharge and 0°C to 45°C for charging, this battery is suitable for both indoor and outdoor use in various climates。

    Send Email Details
  • 12V FT Lead-acid Battery

    12V FT Lead-acid Battery

    1. Good safety performance: no electrolyte leakage, no battery expansion and rupture under normal use. 2, good discharge performance: stable discharge voltage, gentle discharge platform. 3. The battery in fully charged state is completely fixed and vibrated for 1 hour with an amplitude of 4mm and a frequency of 16.7Hz, without leakage, without battery expansion and rupture, and the open-circuit voltage is normal. 4. A fully charged battery with good impact resistance falls naturally from a height of 20cm to a hard board of 1cm thickness for 3 times. No leakage, no battery expansion and rupture open circuit voltage is normal. 5, over discharge resistance of 25 degrees Celsius, fully charged state of the battery for 3 weeks of constant resistance discharge (resistance value is equivalent to the battery 1CA discharge resistance requirements), the recovery capacity is more than 75%. 6, good overcharging resistance :25 degrees Celsius, fully charged state of the battery 0.1CA charge 48 hours, no leakage no battery expansion and rupture open circuit voltage is normal, capacity maintenance rate of more than 95%. 7, high current resistance good fully charged state of the battery 2CA discharge for 5 minutes or 10CA discharge for 5 seconds. No conductive part is fused. No appearance deformation.

    Send Email Details
  • 12V High-capacity Valve-regulated Lead Acid Battery

    12V High-capacity Valve-regulated Lead Acid Battery

    Strictly comply with [ISO] quality management system,products have passed [UL,CE,IEC,ROHS,SONCAP,SASO,PVOC,] and other certifications.We aim to provide the [green,energy-saving and safe electrical energy safety emergency products] for global users.

    Send Email Details
  • 12V Valve-regulated Lead Acid Battery

    12V Valve-regulated Lead Acid Battery

    There are three primary types of VRLA batteries, sealed VR wet cell, absorbent glass mat (AGM) and GEL cell. Gel cells add silica dust to the electrolyte, forming a thick putty-like GEL. These are sometimes referred to as "silicone batteries". AGM (absorbent glass mat) batteries feature fiberglass mesh between the battery plates which serves to contain the electrolyte.

    Send Email Details
  • 6V Lead-acid Battery

    6V Lead-acid Battery

    Maintenance-Free Operation Absorbent Glass Mat (AGM) technology ensures efficient gas recombination up to 99% And f reedom from electrolyte maintenance. During the expected float service life of CBB Batteries, no need to check the specific gravity of the electrolyte or add water.

    Send Email Details
  • EV Series Lead-acid Battery

    EV Series Lead-acid Battery

    1. Good safety performance: no electrolyte leakage, no battery expansion and rupture under normal use. 2, good discharge performance: stable discharge voltage, gentle discharge platform. 3. The battery in fully charged state is completely fixed and vibrated for 1 hour with an amplitude of 4mm and a frequency of 16.7Hz, without leakage, without battery expansion and rupture, and the open-circuit voltage is normal. 4. A fully charged battery with good impact resistance falls naturally from a height of 20cm to a hard board of 1cm thickness for 3 times. No leakage, no battery expansion and rupture open circuit voltage is normal. 5, over discharge resistance of 25 degrees Celsius, fully charged state of the battery for 3 weeks of constant resistance discharge (resistance value is equivalent to the battery 1CA discharge resistance requirements), the recovery capacity is more than 75%. 6, good overcharging resistance :25 degrees Celsius, fully charged state of the battery 0.1CA charge 48 hours, no leakage no battery expansion and rupture open circuit voltage is normal, capacity maintenance rate of more than 95%. 7, high current resistance good fully charged state of the battery 2CA discharge for 5 minutes or 10CA discharge for 5 seconds. No conductive part is fused. No appearance deformation.

    Send Email Details
  • 24V Lead To Lithium UPS Battery

    24V Lead To Lithium UPS Battery

    1. High Temperature Resistant 2. Greater vibration resistance

    Send Email Details
  • 6V UPS Lithium Backup Battery

    6V UPS Lithium Backup Battery

    1. High Temperature Resistant 2. Greater vibration resistance

    Send Email Details
  • 12V Lithium Iron Battery

    12V Lithium Iron Battery

    1. Short circuit test, no explosion, no fire 2. Heating test, no explosion, no fire 3. High safety:Over-charging test,no explosion,no fire,over-current,short circuit

    Send Email Details
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy